Περιγραφή
Kingfisher Triple SM OLTS Kit KI27010 InGaAs APC Refurbished.
Τεχνικά Χαρακτηριστικά
- Easy to use, slim, rugged & versatile.
- Excellent source stability.
- Large clear LCD is sunlight readable & backlit.
- Large memory with Text Tag & time stamp.
- One button memory dump to USB Flash Drive.
- KITS™ reporting software for acquisition and reporting.
- Autotest power meter 1 % accuracy & 25 calibrated λ.
- Traceable calibration reports: power meter & linearity, source λ & stability.
- Interchangeable connectors with dust cap & tilt bail.
- Multi-Fiber ID Test tone generator / detector.
- Long alkaline battery life with micro USB external power / charger.
Detector type (meter) | InGaAs |
Response wavelength (meter) | 600 ~ 1700 nm |
Calibration wavelengths (meter) | 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm |
Power range (meter) | +10 ~ -60 dBm (780 ~ 980 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm) |
Mid-range linearity (meter) | 0.04 dB (typical) |
ID tone detection & Autotest sensitivity (meter) | Up to -50 dBm |
Modulated output (source) | 270 Hz, 1 kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones |
Output wavelength (source) | Port 1: 1310-1550-1625 nm Laser APC |
Output power (source) | -3 dBm ±1 dB (@ SMF) |
Adjust output power (source) | Adjustable over 7 dB in 0.01 dB steps |
Wavelength initial tolerance @ 25 °C (source) | 20 nm |
Short term stability for 15 min, typical ±2 °C, after warm up, ORL < -25 dB (source) | 0.04 dB. |
Stability over temperature (source) | 0.6 dB (typical) |
Spectrum width @ FWHM (source) | 3 nm (typical) |
Wavelength drift (source) | 0.4 nm per °C (typical) |
Reconnection repeatability @ 95% confidence (source) | 0.1 dB |
General Loss Test Set KI 2700 Series specifications
Calibration accuracy (meter) | 1 % (0.06 dB) |
Calibration validity (ISO/IEC 17025) | 3 years |
Resolution (meter) | 0.01 dB |
Polarization sensitivity (meter) | < 0.05 dB (typical) |
Wavelength sensitivity (± 30 nm) | 0.2 dB (typical) |
Autotest | 1-way: compatible with Kingfisher’s 1-way Loss Test Sets & Power Meters (except KI9600 series) |
Tone detection (meter) | 150 ~ 9900 Hz ± 1 % |
Battery life | Laser/LED source: 90/80 hours (typical) in Autotest |
Power | Battery / External power via micro-USB |
Battery type | 2x AA (LR6) Alkaline / 2x AA NiMH AA. |
USB interfaces | micro-USB for power & software / USB-A Flash Drive |
Auto off | Selectable |
Software | KITS (free download) |
Memory | 1,000 four λ tests with date & time / Unlimited on USB Flash Drive |
Case | Polycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested |
Display size | 74 mm x 55 mm |
Size | 190 mm x 105 mm x 35 mm |
Unit weight | 0.42 kg |
Shipping weight | 1.5 Kg |
Operating / storage temperature | -15 to 55 °C / -25 to 70 °C |
Relative humidity | 0 ~ 95 % |
Warranty | 3 years |
IP Rating | IP52 |