{"id":4174,"date":"2026-08-06T20:18:28","date_gmt":"2026-08-06T17:18:28","guid":{"rendered":"https:\/\/arctos.gr\/?p=4174"},"modified":"2026-08-06T20:24:32","modified_gmt":"2026-08-06T17:24:32","slug":"sc-apc-vs-sc-upc","status":"publish","type":"post","link":"https:\/\/arctos.gr\/en\/sc-apc-vs-sc-upc\/","title":{"rendered":"SC\/APC vs SC\/UPC: \u03a0\u03bf\u03b9\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2;"},"content":{"rendered":"<h2><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-4175 alignleft\" style=\"font-size: 16px;\" src=\"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos-650x366.png\" alt=\"SC\/APC vs SC\/UPC connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd \u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03bf \u03ba\u03b1\u03b9 \u03bc\u03c0\u03bb\u03b5\" width=\"948\" height=\"534\" srcset=\"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos-650x366.png 650w, https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos-1200x675.png 1200w, https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos-768x432.png 768w, https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos-1536x864.png 1536w, https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos-18x10.png 18w, https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos-600x338.png 600w, https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png 1672w\" sizes=\"(max-width: 948px) 100vw, 948px\" \/><\/h2>\n<p>\u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03b1\u03bd\u03ac\u03bc\u03b5\u03c3\u03b1 \u03c3\u03b5 SC\/APC \u03ba\u03b1\u03b9 SC\/UPC connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd \u03b3\u03b9\u03b1 FTTH, PON \u03ba\u03b1\u03b9 \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03ad\u03c2 \u03b5\u03b3\u03ba\u03b1\u03c4\u03b1\u03c3\u03c4\u03ac\u03c3\u03b5\u03b9\u03c2.<\/p>\n<h2>SC\/APC vs SC\/UPC: \u03b3\u03b9\u03b1\u03c4\u03af \u03ad\u03c7\u03b5\u03b9 \u03c3\u03b7\u03bc\u03b1\u03c3\u03af\u03b1 \u03b7 \u03b5\u03c0\u03b9\u03bb\u03bf\u03b3\u03ae connector;<\/h2>\n<p>The <strong>SC\/APC vs SC\/UPC<\/strong> \u03b5\u03af\u03bd\u03b1\u03b9 \u03ad\u03bd\u03b1 \u03b1\u03c0\u03cc \u03c4\u03b1 \u03c0\u03b9\u03bf \u03c3\u03c5\u03c7\u03bd\u03ac \u03b5\u03c1\u03c9\u03c4\u03ae\u03bc\u03b1\u03c4\u03b1 \u03c3\u03b5 \u03b5\u03b3\u03ba\u03b1\u03c4\u03b1\u03c3\u03c4\u03ac\u03c3\u03b5\u03b9\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd. \u0391\u03c1\u03c7\u03b9\u03ba\u03ac, \u03ba\u03b1\u03b9 \u03c4\u03b1 \u03b4\u03cd\u03bf \u03b5\u03af\u03bd\u03b1\u03b9 connectors \u03c4\u03cd\u03c0\u03bf\u03c5 SC. \u03a9\u03c3\u03c4\u03cc\u03c3\u03bf, \u03b4\u03b9\u03b1\u03c6\u03ad\u03c1\u03bf\u03c5\u03bd \u03c3\u03c4\u03bf\u03bd \u03c4\u03c1\u03cc\u03c0\u03bf \u03b3\u03c5\u03b1\u03bb\u03af\u03c3\u03bc\u03b1\u03c4\u03bf\u03c2 \u03c4\u03b7\u03c2 \u03ac\u03ba\u03c1\u03b7\u03c2 \u03c4\u03b7\u03c2 \u03af\u03bd\u03b1\u03c2, \u03c3\u03c4\u03bf \u03c7\u03c1\u03ce\u03bc\u03b1, \u03c3\u03c4\u03b7\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03bf\u03c6\u03ae \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2 \u03ba\u03b1\u03b9 \u03c3\u03c4\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03c4\u03bf\u03c5\u03c2 \u03bc\u03ad\u03c3\u03b1 \u03c3\u03b5 \u03ad\u03bd\u03b1 \u03b4\u03af\u03ba\u03c4\u03c5\u03bf.<\/p>\n<p>\u0397 \u03c3\u03c9\u03c3\u03c4\u03ae \u03b5\u03c0\u03b9\u03bb\u03bf\u03b3\u03ae connector \u03b5\u03c0\u03b7\u03c1\u03b5\u03ac\u03b6\u03b5\u03b9 \u03c4\u03b7\u03bd \u03c0\u03bf\u03b9\u03cc\u03c4\u03b7\u03c4\u03b1 \u03c4\u03b7\u03c2 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7\u03c2, \u03c4\u03b7\u03bd \u03b1\u03c0\u03ce\u03bb\u03b5\u03b9\u03b1, \u03c4\u03b9\u03c2 \u03b1\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2 \u03ba\u03b1\u03b9 \u03c4\u03b7 \u03c3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc\u03c4\u03b7\u03c4\u03b1 \u03c4\u03bf\u03c5 \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2. \u0395\u03c0\u03bf\u03bc\u03ad\u03bd\u03c9\u03c2, \u03c0\u03c1\u03b9\u03bd \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03b5\u03c4\u03b5 patchcord, adapter \u03ae \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc \u03bc\u03ad\u03c4\u03c1\u03b7\u03c3\u03b7\u03c2, \u03c0\u03c1\u03ad\u03c0\u03b5\u03b9 \u03bd\u03b1 \u03b3\u03bd\u03c9\u03c1\u03af\u03b6\u03b5\u03c4\u03b5 \u03b1\u03bd \u03c4\u03bf \u03b4\u03af\u03ba\u03c4\u03c5\u03bf \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03b5\u03af SC\/APC \u03ae SC\/UPC.<\/p>\n<h2>\u03a4\u03b9 \u03c3\u03b7\u03bc\u03b1\u03af\u03bd\u03b5\u03b9 SC connector;<\/h2>\n<p>\u03a4\u03bf SC \u03b5\u03af\u03bd\u03b1\u03b9 \u03ad\u03bd\u03b1\u03c2 \u03b1\u03c0\u03cc \u03c4\u03bf\u03c5\u03c2 \u03c0\u03b9\u03bf \u03b3\u03bd\u03c9\u03c3\u03c4\u03bf\u03cd\u03c2 \u03c4\u03cd\u03c0\u03bf\u03c5\u03c2 connector \u03c3\u03c4\u03b9\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u03af\u03bd\u03b5\u03c2. \u03a7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03b5\u03af\u03c4\u03b1\u03b9 \u03c3\u03c5\u03c7\u03bd\u03ac \u03c3\u03b5 FTTH, FTTx, patch panels, \u03bf\u03c0\u03c4\u03b9\u03ba\u03bf\u03cd\u03c2 \u03ba\u03b1\u03c4\u03b1\u03bd\u03b5\u03bc\u03b7\u03c4\u03ad\u03c2, ODF, ONT, OLT \u03ba\u03b1\u03b9 \u03cc\u03c1\u03b3\u03b1\u03bd\u03b1 \u03bc\u03ad\u03c4\u03c1\u03b7\u03c3\u03b7\u03c2. \u0395\u03c0\u03b9\u03c0\u03bb\u03ad\u03bf\u03bd, \u03b4\u03b9\u03b1\u03b8\u03ad\u03c4\u03b5\u03b9 \u03bc\u03b7\u03c7\u03b1\u03bd\u03b9\u03c3\u03bc\u03cc push-pull, \u03bf \u03bf\u03c0\u03bf\u03af\u03bf\u03c2 \u03ba\u03ac\u03bd\u03b5\u03b9 \u03c4\u03b7 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7 \u03b3\u03c1\u03ae\u03b3\u03bf\u03c1\u03b7 \u03ba\u03b1\u03b9 \u03c3\u03c4\u03b1\u03b8\u03b5\u03c1\u03ae.<\/p>\n<p>\u03a0\u03b1\u03c1\u03cc\u03bb\u03b1 \u03b1\u03c5\u03c4\u03ac, \u03c4\u03bf SC \u03b1\u03c0\u03cc \u03bc\u03cc\u03bd\u03bf \u03c4\u03bf\u03c5 \u03b4\u03b5\u03bd \u03bc\u03b1\u03c2 \u03bb\u03ad\u03b5\u03b9 \u03b1\u03bd \u03bf connector \u03b5\u03af\u03bd\u03b1\u03b9 APC \u03ae UPC. \u03a4\u03bf SC \u03b4\u03b5\u03af\u03c7\u03bd\u03b5\u03b9 \u03c4\u03bf\u03bd \u03bc\u03b7\u03c7\u03b1\u03bd\u03b9\u03ba\u03cc \u03c4\u03cd\u03c0\u03bf \u03c4\u03bf\u03c5 connector. \u0391\u03bd\u03c4\u03af\u03b8\u03b5\u03c4\u03b1, \u03c4\u03bf APC \u03ba\u03b1\u03b9 \u03c4\u03bf UPC \u03b4\u03b5\u03af\u03c7\u03bd\u03bf\u03c5\u03bd \u03c4\u03bf\u03bd \u03c4\u03c1\u03cc\u03c0\u03bf \u03b3\u03c5\u03b1\u03bb\u03af\u03c3\u03bc\u03b1\u03c4\u03bf\u03c2 \u03c4\u03b7\u03c2 \u03b5\u03c0\u03b9\u03c6\u03ac\u03bd\u03b5\u03b9\u03b1\u03c2 \u03c4\u03b7\u03c2 \u03af\u03bd\u03b1\u03c2.<\/p>\n<h2>\u03a4\u03b9 \u03b5\u03af\u03bd\u03b1\u03b9 \u03c4\u03bf SC\/APC;<\/h2>\n<p>The <strong>SC\/APC<\/strong> \u03c3\u03b7\u03bc\u03b1\u03af\u03bd\u03b5\u03b9 Angled Physical Contact. \u0394\u03b7\u03bb\u03b1\u03b4\u03ae, \u03b7 \u03ac\u03ba\u03c1\u03b7 \u03c4\u03b7\u03c2 \u03af\u03bd\u03b1\u03c2 \u03ad\u03c7\u03b5\u03b9 \u03b3\u03c5\u03b1\u03bb\u03b9\u03c3\u03c4\u03b5\u03af \u03c5\u03c0\u03cc \u03b3\u03c9\u03bd\u03af\u03b1. \u03a3\u03c5\u03bd\u03ae\u03b8\u03c9\u03c2, \u03bf SC\/APC connector \u03ad\u03c7\u03b5\u03b9 \u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03bf \u03c7\u03c1\u03ce\u03bc\u03b1, \u03ce\u03c3\u03c4\u03b5 \u03bf \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03cc\u03c2 \u03bd\u03b1 \u03c4\u03bf\u03bd \u03be\u03b5\u03c7\u03c9\u03c1\u03af\u03b6\u03b5\u03b9 \u03b3\u03c1\u03ae\u03b3\u03bf\u03c1\u03b1 \u03c3\u03c4\u03bf \u03c0\u03b5\u03b4\u03af\u03bf.<\/p>\n<p>\u03a4\u03bf \u03b2\u03b1\u03c3\u03b9\u03ba\u03cc \u03c0\u03bb\u03b5\u03bf\u03bd\u03ad\u03ba\u03c4\u03b7\u03bc\u03b1 \u03c4\u03bf\u03c5 SC\/APC \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u03c7\u03b1\u03bc\u03b7\u03bb\u03ae \u03b1\u03bd\u03ac\u03ba\u03bb\u03b1\u03c3\u03b7 \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2. \u0395\u03c0\u03b5\u03b9\u03b4\u03ae \u03b7 \u03b5\u03c0\u03b9\u03c6\u03ac\u03bd\u03b5\u03b9\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b3\u03c9\u03bd\u03b9\u03b1\u03ba\u03ae, \u03c4\u03bf \u03b1\u03bd\u03b1\u03ba\u03bb\u03ce\u03bc\u03b5\u03bd\u03bf \u03c6\u03c9\u03c2 \u03b4\u03b5\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03ad\u03c6\u03b5\u03b9 \u03b5\u03cd\u03ba\u03bf\u03bb\u03b1 \u03c0\u03c1\u03bf\u03c2 \u03c4\u03b7\u03bd \u03c0\u03b7\u03b3\u03ae. \u0388\u03c4\u03c3\u03b9, \u03c4\u03bf SC\/APC \u03c4\u03b1\u03b9\u03c1\u03b9\u03ac\u03b6\u03b5\u03b9 \u03c0\u03bf\u03bb\u03cd \u03ba\u03b1\u03bb\u03ac \u03c3\u03b5 FTTH, GPON, XGS-PON, CATV \u03ba\u03b1\u03b9 \u03b3\u03b5\u03bd\u03b9\u03ba\u03ac \u03c3\u03b5 \u03b4\u03af\u03ba\u03c4\u03c5\u03b1 \u03c0\u03bf\u03c5 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b5\u03c5\u03b1\u03af\u03c3\u03b8\u03b7\u03c4\u03b1 \u03c3\u03c4\u03b9\u03c2 \u03b1\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2.<\/p>\n<h2>\u03a4\u03b9 \u03b5\u03af\u03bd\u03b1\u03b9 \u03c4\u03bf SC\/UPC;<\/h2>\n<p>The <strong>SC\/UPC<\/strong> \u03c3\u03b7\u03bc\u03b1\u03af\u03bd\u03b5\u03b9 Ultra Physical Contact. \u03a3\u03b5 \u03b1\u03c5\u03c4\u03ae \u03c4\u03b7\u03bd \u03c0\u03b5\u03c1\u03af\u03c0\u03c4\u03c9\u03c3\u03b7, \u03b7 \u03b5\u03c0\u03b9\u03c6\u03ac\u03bd\u03b5\u03b9\u03b1 \u03c4\u03b7\u03c2 \u03af\u03bd\u03b1\u03c2 \u03ad\u03c7\u03b5\u03b9 \u03b3\u03c5\u03b1\u03bb\u03b9\u03c3\u03c4\u03b5\u03af \u03c7\u03c9\u03c1\u03af\u03c2 \u03b3\u03c9\u03bd\u03af\u03b1, \u03bc\u03b5 \u03c0\u03bf\u03bb\u03cd \u03ba\u03b1\u03bb\u03ae \u03b5\u03c0\u03b1\u03c6\u03ae \u03bc\u03b5\u03c4\u03b1\u03be\u03cd \u03c4\u03c9\u03bd \u03b4\u03cd\u03bf connector. \u03a3\u03c5\u03bd\u03ae\u03b8\u03c9\u03c2, \u03bf SC\/UPC connector \u03ad\u03c7\u03b5\u03b9 \u03bc\u03c0\u03bb\u03b5 \u03c7\u03c1\u03ce\u03bc\u03b1.<\/p>\n<p>\u03a4\u03bf SC\/UPC \u03c0\u03c1\u03bf\u03c3\u03c6\u03ad\u03c1\u03b5\u03b9 \u03ba\u03b1\u03bb\u03ae \u03b1\u03c0\u03cc\u03b4\u03bf\u03c3\u03b7 \u03ba\u03b1\u03b9 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03b5\u03af\u03c4\u03b1\u03b9 \u03c3\u03b5 \u03c0\u03bf\u03bb\u03bb\u03ad\u03c2 \u03b5\u03c6\u03b1\u03c1\u03bc\u03bf\u03b3\u03ad\u03c2 \u03b4\u03b9\u03ba\u03c4\u03cd\u03c9\u03bd. \u0393\u03b9\u03b1 \u03c0\u03b1\u03c1\u03ac\u03b4\u03b5\u03b9\u03b3\u03bc\u03b1, \u03bc\u03c0\u03bf\u03c1\u03b5\u03af \u03bd\u03b1 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03b7\u03b8\u03b5\u03af \u03c3\u03b5 data networks, patch panels, \u03b5\u03c1\u03b3\u03b1\u03c3\u03c4\u03b7\u03c1\u03b9\u03b1\u03ba\u03ad\u03c2 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c3\u03b5\u03b9\u03c2 \u03ba\u03b1\u03b9 \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc \u03c0\u03bf\u03c5 \u03b1\u03c0\u03b1\u03b9\u03c4\u03b5\u03af UPC interface. \u03a9\u03c3\u03c4\u03cc\u03c3\u03bf, \u03c3\u03b5 \u03b5\u03c6\u03b1\u03c1\u03bc\u03bf\u03b3\u03ad\u03c2 FTTH \u03ba\u03b1\u03b9 PON, \u03c4\u03bf SC\/APC \u03b5\u03af\u03bd\u03b1\u03b9 \u03c3\u03c5\u03c7\u03bd\u03ac \u03b7 \u03c0\u03c1\u03bf\u03c4\u03b9\u03bc\u03cc\u03c4\u03b5\u03c1\u03b7 \u03b5\u03c0\u03b9\u03bb\u03bf\u03b3\u03ae, \u03b5\u03c0\u03b5\u03b9\u03b4\u03ae \u03bc\u03b5\u03b9\u03ce\u03bd\u03b5\u03b9 \u03c0\u03b5\u03c1\u03b9\u03c3\u03c3\u03cc\u03c4\u03b5\u03c1\u03bf \u03c4\u03b9\u03c2 \u03b1\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2.<\/p>\n<h2>SC\/APC vs SC\/UPC: \u03b2\u03b1\u03c3\u03b9\u03ba\u03ad\u03c2 \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2<\/h2>\n<p>\u0397 \u03b2\u03b1\u03c3\u03b9\u03ba\u03ae \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03c3\u03c4\u03bf <strong>SC\/APC vs SC\/UPC<\/strong> \u03b2\u03c1\u03af\u03c3\u03ba\u03b5\u03c4\u03b1\u03b9 \u03c3\u03c4\u03bf \u03b3\u03c5\u03ac\u03bb\u03b9\u03c3\u03bc\u03b1 \u03c4\u03b7\u03c2 \u03ac\u03ba\u03c1\u03b7\u03c2 \u03c4\u03b7\u03c2 \u03af\u03bd\u03b1\u03c2. \u03a4\u03bf SC\/APC \u03ad\u03c7\u03b5\u03b9 \u03b3\u03c9\u03bd\u03b9\u03b1\u03ba\u03cc \u03b3\u03c5\u03ac\u03bb\u03b9\u03c3\u03bc\u03b1, \u03b5\u03bd\u03ce \u03c4\u03bf SC\/UPC \u03ad\u03c7\u03b5\u03b9 \u03af\u03c3\u03b9\u03bf, \u03c0\u03bf\u03bb\u03cd \u03c0\u03c1\u03bf\u03c3\u03b5\u03b3\u03bc\u03ad\u03bd\u03bf \u03b3\u03c5\u03ac\u03bb\u03b9\u03c3\u03bc\u03b1. \u0391\u03c5\u03c4\u03ae \u03b7 \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03b1\u03bb\u03bb\u03ac\u03b6\u03b5\u03b9 \u03c4\u03b7\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03bf\u03c6\u03ae \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2 \u03ba\u03b1\u03b9 \u03c4\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03ba\u03ac\u03b8\u03b5 connector.<\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>\u03a7\u03b1\u03c1\u03b1\u03ba\u03c4\u03b7\u03c1\u03b9\u03c3\u03c4\u03b9\u03ba\u03cc<\/strong><\/td>\n<td><strong>SC\/APC<\/strong><\/td>\n<td><strong>SC\/UPC<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u03a7\u03c1\u03ce\u03bc\u03b1 connector<\/td>\n<td>green<\/td>\n<td>\u039c\u03c0\u03bb\u03b5<\/td>\n<\/tr>\n<tr>\n<td>\u03a4\u03cd\u03c0\u03bf\u03c2 \u03b3\u03c5\u03b1\u03bb\u03af\u03c3\u03bc\u03b1\u03c4\u03bf\u03c2<\/td>\n<td>\u0393\u03c9\u03bd\u03b9\u03b1\u03ba\u03cc \u03b3\u03c5\u03ac\u03bb\u03b9\u03c3\u03bc\u03b1<\/td>\n<td>Ultra Physical Contact<\/td>\n<\/tr>\n<tr>\n<td>\u0391\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2<\/td>\n<td>\u03a0\u03bf\u03bb\u03cd \u03c7\u03b1\u03bc\u03b7\u03bb\u03ad\u03c2<\/td>\n<td>\u03a7\u03b1\u03bc\u03b7\u03bb\u03ad\u03c2, \u03b1\u03bb\u03bb\u03ac \u03c3\u03c5\u03bd\u03ae\u03b8\u03c9\u03c2 \u03c5\u03c8\u03b7\u03bb\u03cc\u03c4\u03b5\u03c1\u03b5\u03c2 \u03b1\u03c0\u03cc APC<\/td>\n<\/tr>\n<tr>\n<td>\u03a3\u03c5\u03bd\u03b7\u03b8\u03b9\u03c3\u03bc\u03ad\u03bd\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7<\/td>\n<td>FTTH, GPON, XGS-PON, CATV, PON \u03b4\u03af\u03ba\u03c4\u03c5\u03b1<\/td>\n<td>Data networks, patch panels, \u03b5\u03c1\u03b3\u03b1\u03c3\u03c4\u03b7\u03c1\u03b9\u03b1\u03ba\u03ad\u03c2 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c3\u03b5\u03b9\u03c2<\/td>\n<\/tr>\n<tr>\n<td>\u03a3\u03c5\u03bc\u03b2\u03b1\u03c4\u03cc\u03c4\u03b7\u03c4\u03b1<\/td>\n<td>\u03a3\u03c5\u03bd\u03b4\u03ad\u03b5\u03c4\u03b1\u03b9 \u03bc\u03cc\u03bd\u03bf \u03bc\u03b5 APC<\/td>\n<td>\u03a3\u03c5\u03bd\u03b4\u03ad\u03b5\u03c4\u03b1\u03b9 \u03bc\u03cc\u03bd\u03bf \u03bc\u03b5 UPC\/PC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u039c\u03c0\u03bf\u03c1\u03ce \u03bd\u03b1 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c3\u03c9 SC\/APC \u03bc\u03b5 SC\/UPC;<\/h2>\n<p>\u038c\u03c7\u03b9, \u03b4\u03b5\u03bd \u03c0\u03c1\u03ad\u03c0\u03b5\u03b9 \u03bd\u03b1 \u03c3\u03c5\u03bd\u03b4\u03ad\u03b5\u03c4\u03b5 \u03b1\u03c0\u03b5\u03c5\u03b8\u03b5\u03af\u03b1\u03c2 <strong>SC\/APC \u03bc\u03b5 SC\/UPC<\/strong>. \u03a0\u03b1\u03c1\u03cc\u03bb\u03bf \u03c0\u03bf\u03c5 \u03b5\u03be\u03c9\u03c4\u03b5\u03c1\u03b9\u03ba\u03ac \u03bc\u03bf\u03b9\u03ac\u03b6\u03bf\u03c5\u03bd \u03ba\u03b1\u03b9 \u03bc\u03c0\u03b1\u03af\u03bd\u03bf\u03c5\u03bd \u03c3\u03b5 SC adapter, \u03b7 \u03b5\u03c0\u03b9\u03c6\u03ac\u03bd\u03b5\u03b9\u03b1 \u03c4\u03b7\u03c2 \u03af\u03bd\u03b1\u03c2 \u03b4\u03b5\u03bd \u03b5\u03af\u03bd\u03b1\u03b9 \u03af\u03b4\u03b9\u03b1. \u03a4\u03bf SC\/APC \u03ad\u03c7\u03b5\u03b9 \u03b3\u03c9\u03bd\u03af\u03b1, \u03b5\u03bd\u03ce \u03c4\u03bf SC\/UPC \u03b4\u03b5\u03bd \u03ad\u03c7\u03b5\u03b9 \u03c4\u03b7\u03bd \u03af\u03b4\u03b9\u03b1 \u03b3\u03c9\u03bd\u03b9\u03b1\u03ba\u03ae \u03b5\u03c0\u03b1\u03c6\u03ae.<\/p>\n<p>\u0391\u03bd \u03c4\u03b1 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c3\u03b5\u03c4\u03b5 \u03bc\u03b5\u03c4\u03b1\u03be\u03cd \u03c4\u03bf\u03c5\u03c2, \u03bc\u03c0\u03bf\u03c1\u03b5\u03af \u03bd\u03b1 \u03b1\u03c5\u03be\u03b7\u03b8\u03b5\u03af \u03b7 \u03b1\u03c0\u03ce\u03bb\u03b5\u03b9\u03b1, \u03bd\u03b1 \u03b4\u03b7\u03bc\u03b9\u03bf\u03c5\u03c1\u03b3\u03b7\u03b8\u03bf\u03cd\u03bd \u03ad\u03bd\u03c4\u03bf\u03bd\u03b5\u03c2 \u03b1\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2 \u03ba\u03b1\u03b9 \u03bd\u03b1 \u03c0\u03c1\u03bf\u03ba\u03bb\u03b7\u03b8\u03b5\u03af \u03c6\u03b8\u03bf\u03c1\u03ac \u03c3\u03c4\u03b9\u03c2 \u03b5\u03c0\u03b9\u03c6\u03ac\u03bd\u03b5\u03b9\u03b5\u03c2 \u03c4\u03c9\u03bd connector. \u0395\u03c0\u03bf\u03bc\u03ad\u03bd\u03c9\u03c2, \u03bf \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03cc\u03c2 \u03c0\u03c1\u03ad\u03c0\u03b5\u03b9 \u03c0\u03ac\u03bd\u03c4\u03b1 \u03bd\u03b1 \u03c4\u03b1\u03b9\u03c1\u03b9\u03ac\u03b6\u03b5\u03b9 APC \u03bc\u03b5 APC \u03ba\u03b1\u03b9 UPC \u03bc\u03b5 UPC.<\/p>\n<h2>\u03a0\u03cc\u03c4\u03b5 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bc\u03b5 SC\/APC;<\/h2>\n<p>\u03a4\u03bf SC\/APC \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u03c0\u03b9\u03bf \u03c3\u03c5\u03bd\u03b7\u03b8\u03b9\u03c3\u03bc\u03ad\u03bd\u03b7 \u03b5\u03c0\u03b9\u03bb\u03bf\u03b3\u03ae \u03c3\u03b5 FTTH \u03ba\u03b1\u03b9 PON \u03b5\u03b3\u03ba\u03b1\u03c4\u03b1\u03c3\u03c4\u03ac\u03c3\u03b5\u03b9\u03c2. \u0395\u03c0\u03b9\u03c0\u03bb\u03ad\u03bf\u03bd, \u03c4\u03bf \u03c3\u03c5\u03bd\u03b1\u03bd\u03c4\u03ac\u03bc\u03b5 \u03c3\u03c5\u03c7\u03bd\u03ac \u03c3\u03b5 ONT, OLT, splitter, \u03ba\u03b1\u03bc\u03c0\u03af\u03bd\u03b5\u03c2, \u03bf\u03c0\u03c4\u03b9\u03ba\u03bf\u03cd\u03c2 \u03ba\u03b1\u03c4\u03b1\u03bd\u03b5\u03bc\u03b7\u03c4\u03ad\u03c2 \u03ba\u03b1\u03b9 patchcords \u03b3\u03b9\u03b1 \u03bf\u03b9\u03ba\u03b9\u03b1\u03ba\u03ad\u03c2 \u03ae \u03b5\u03c0\u03b1\u03b3\u03b3\u03b5\u03bb\u03bc\u03b1\u03c4\u03b9\u03ba\u03ad\u03c2 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c3\u03b5\u03b9\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd.<\/p>\n<p>\u0395\u03c0\u03b9\u03bb\u03ad\u03b3\u03bf\u03c5\u03bc\u03b5 SC\/APC \u03cc\u03c4\u03b1\u03bd \u03b8\u03ad\u03bb\u03bf\u03c5\u03bc\u03b5 \u03bd\u03b1 \u03c0\u03b5\u03c1\u03b9\u03bf\u03c1\u03af\u03c3\u03bf\u03c5\u03bc\u03b5 \u03c4\u03b9\u03c2 \u03b1\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2 \u03ba\u03b1\u03b9 \u03bd\u03b1 \u03ba\u03c1\u03b1\u03c4\u03ae\u03c3\u03bf\u03c5\u03bc\u03b5 \u03c4\u03bf \u03b4\u03af\u03ba\u03c4\u03c5\u03bf \u03c3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc. \u0393\u03b9\u03b1 \u03b1\u03c5\u03c4\u03cc\u03bd \u03c4\u03bf\u03bd \u03bb\u03cc\u03b3\u03bf, \u03c4\u03b1 \u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03b1 connectors \u03b5\u03af\u03bd\u03b1\u03b9 \u03c0\u03bf\u03bb\u03cd \u03c3\u03c5\u03c7\u03bd\u03ac \u03c3\u03b5 \u03c4\u03b7\u03bb\u03b5\u03c0\u03b9\u03ba\u03bf\u03b9\u03bd\u03c9\u03bd\u03b9\u03b1\u03ba\u03ac \u03b4\u03af\u03ba\u03c4\u03c5\u03b1 \u03ba\u03b1\u03b9 \u03b5\u03b3\u03ba\u03b1\u03c4\u03b1\u03c3\u03c4\u03ac\u03c3\u03b5\u03b9\u03c2 FTTH.<\/p>\n<h2>\u03a0\u03cc\u03c4\u03b5 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bc\u03b5 SC\/UPC;<\/h2>\n<p>\u03a4\u03bf SC\/UPC \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03b5\u03af\u03c4\u03b1\u03b9 \u03cc\u03c4\u03b1\u03bd \u03bf \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u03b4\u03b9\u03b1\u03b8\u03ad\u03c4\u03b5\u03b9 UPC \u03b8\u03cd\u03c1\u03b5\u03c2. \u0393\u03b9\u03b1 \u03c0\u03b1\u03c1\u03ac\u03b4\u03b5\u03b9\u03b3\u03bc\u03b1, \u03bc\u03c0\u03bf\u03c1\u03b5\u03af \u03bd\u03b1 \u03c4\u03bf \u03c3\u03c5\u03bd\u03b1\u03bd\u03c4\u03ae\u03c3\u03bf\u03c5\u03bc\u03b5 \u03c3\u03b5 \u03bf\u03c1\u03b9\u03c3\u03bc\u03ad\u03bd\u03b1 patch panels, media converters, switches, \u03b5\u03c1\u03b3\u03b1\u03c3\u03c4\u03b7\u03c1\u03b9\u03b1\u03ba\u03ad\u03c2 \u03b4\u03b9\u03b1\u03c4\u03ac\u03be\u03b5\u03b9\u03c2 \u03ba\u03b1\u03b9 \u03c3\u03c5\u03c3\u03ba\u03b5\u03c5\u03ad\u03c2 \u03bc\u03ad\u03c4\u03c1\u03b7\u03c3\u03b7\u03c2.<\/p>\n<p>\u03a9\u03c3\u03c4\u03cc\u03c3\u03bf, \u03c0\u03c1\u03b9\u03bd \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03ae\u03c3\u03b5\u03c4\u03b5 SC\/UPC \u03c3\u03b5 \u03b5\u03b3\u03ba\u03b1\u03c4\u03ac\u03c3\u03c4\u03b1\u03c3\u03b7 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd, \u03b5\u03bb\u03ad\u03b3\u03be\u03c4\u03b5 \u03c0\u03ac\u03bd\u03c4\u03b1 \u03c4\u03b7 \u03b8\u03cd\u03c1\u03b1 \u03c4\u03bf\u03c5 \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03bf\u03cd. \u0391\u03bd \u03b7 \u03b8\u03cd\u03c1\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03b7 \u03ae \u03b3\u03c1\u03ac\u03c6\u03b5\u03b9 APC, \u03c4\u03cc\u03c4\u03b5 \u03c7\u03c1\u03b5\u03b9\u03ac\u03b6\u03b5\u03c4\u03b1\u03b9 SC\/APC patchcord. \u0391\u03bd \u03b7 \u03b8\u03cd\u03c1\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03bc\u03c0\u03bb\u03b5 \u03ae \u03b3\u03c1\u03ac\u03c6\u03b5\u03b9 UPC, \u03c4\u03cc\u03c4\u03b5 \u03c7\u03c1\u03b5\u03b9\u03ac\u03b6\u03b5\u03c4\u03b1\u03b9 SC\/UPC patchcord.<\/p>\n<h2>\u03a0\u03ce\u03c2 \u03be\u03b5\u03c7\u03c9\u03c1\u03af\u03b6\u03c9 \u03b3\u03c1\u03ae\u03b3\u03bf\u03c1\u03b1 SC\/APC \u03ba\u03b1\u03b9 SC\/UPC \u03c3\u03c4\u03bf \u03c0\u03b5\u03b4\u03af\u03bf;<\/h2>\n<p>\u039f \u03c0\u03b9\u03bf \u03b1\u03c0\u03bb\u03cc\u03c2 \u03c4\u03c1\u03cc\u03c0\u03bf\u03c2 \u03b5\u03af\u03bd\u03b1\u03b9 \u03c4\u03bf \u03c7\u03c1\u03ce\u03bc\u03b1. \u03a3\u03c5\u03bd\u03ae\u03b8\u03c9\u03c2, \u03c4\u03bf \u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03bf \u03c7\u03c1\u03ce\u03bc\u03b1 \u03b4\u03b5\u03af\u03c7\u03bd\u03b5\u03b9 SC\/APC, \u03b5\u03bd\u03ce \u03c4\u03bf \u03bc\u03c0\u03bb\u03b5 \u03c7\u03c1\u03ce\u03bc\u03b1 \u03b4\u03b5\u03af\u03c7\u03bd\u03b5\u03b9 SC\/UPC. \u03a0\u03b1\u03c1\u03ac\u03bb\u03bb\u03b7\u03bb\u03b1, \u03c0\u03bf\u03bb\u03bb\u03ad\u03c2 \u03c3\u03c5\u03c3\u03ba\u03b5\u03c5\u03ad\u03c2 \u03b3\u03c1\u03ac\u03c6\u03bf\u03c5\u03bd \u03b4\u03af\u03c0\u03bb\u03b1 \u03c3\u03c4\u03b7 \u03b8\u03cd\u03c1\u03b1 APC \u03ae UPC.<\/p>\n<p>\u0395\u03c0\u03b9\u03c0\u03bb\u03ad\u03bf\u03bd, \u03c0\u03c1\u03ad\u03c0\u03b5\u03b9 \u03bd\u03b1 \u03b5\u03bb\u03ad\u03b3\u03c7\u03b5\u03c4\u03b5 \u03c4\u03b7\u03bd \u03c0\u03b5\u03c1\u03b9\u03b3\u03c1\u03b1\u03c6\u03ae \u03c4\u03bf\u03c5 patchcord \u03ae \u03c4\u03bf\u03c5 adapter. \u0393\u03b9\u03b1 \u03c0\u03b1\u03c1\u03ac\u03b4\u03b5\u03b9\u03b3\u03bc\u03b1, \u03ad\u03bd\u03b1 patchcord \u03bc\u03c0\u03bf\u03c1\u03b5\u03af \u03bd\u03b1 \u03b3\u03c1\u03ac\u03c6\u03b5\u03b9 SC\/APC\u2013SC\/APC \u03ae SC\/UPC\u2013SC\/UPC. \u0388\u03c4\u03c3\u03b9, \u03b1\u03c0\u03bf\u03c6\u03b5\u03cd\u03b3\u03b5\u03c4\u03b5 \u03bb\u03ac\u03b8\u03bf\u03c2 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7 \u03ba\u03b1\u03b9 \u03bc\u03b5\u03b9\u03ce\u03bd\u03b5\u03c4\u03b5 \u03c4\u03bf\u03bd \u03ba\u03af\u03bd\u03b4\u03c5\u03bd\u03bf \u03c0\u03c1\u03bf\u03b2\u03bb\u03b7\u03bc\u03ac\u03c4\u03c9\u03bd \u03c3\u03c4\u03b7 \u03b3\u03c1\u03b1\u03bc\u03bc\u03ae.<\/p>\n<h2>\u03a4\u03b9 \u03b3\u03af\u03bd\u03b5\u03c4\u03b1\u03b9 \u03bc\u03b5 \u03c4\u03b1 patchcords SC\/APC\u2013SC\/APC;<\/h2>\n<p>\u03a4\u03b1 patchcords <strong>SC\/APC\u2013SC\/APC<\/strong> \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bd\u03c4\u03b1\u03b9 \u03cc\u03c4\u03b1\u03bd \u03ba\u03b1\u03b9 \u03bf\u03b9 \u03b4\u03cd\u03bf \u03c0\u03bb\u03b5\u03c5\u03c1\u03ad\u03c2 \u03c4\u03b7\u03c2 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7\u03c2 \u03b1\u03c0\u03b1\u03b9\u03c4\u03bf\u03cd\u03bd APC connector. \u0395\u03af\u03bd\u03b1\u03b9 \u03c0\u03bf\u03bb\u03cd \u03c3\u03c5\u03c7\u03bd\u03ac \u03c3\u03b5 FTTH \u03b5\u03b3\u03ba\u03b1\u03c4\u03b1\u03c3\u03c4\u03ac\u03c3\u03b5\u03b9\u03c2, \u03bf\u03c0\u03c4\u03b9\u03ba\u03bf\u03cd\u03c2 \u03ba\u03b1\u03c4\u03b1\u03bd\u03b5\u03bc\u03b7\u03c4\u03ad\u03c2 \u03ba\u03b1\u03b9 \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc PON.<\/p>\n<p>\u03a3\u03c4\u03bf eshop \u03c4\u03b7\u03c2 ARCTOS \u03bc\u03c0\u03bf\u03c1\u03b5\u03af\u03c4\u03b5 \u03bd\u03b1 \u03b2\u03c1\u03b5\u03af\u03c4\u03b5 \u03b5\u03c0\u03b1\u03b3\u03b3\u03b5\u03bb\u03bc\u03b1\u03c4\u03b9\u03ba\u03ac <a href=\"https:\/\/arctos.gr\/en\/product\/patchcord-optikis-inas-sc-apc-50m\/\">patchcord SC\/APC 50m<\/a> and <a href=\"https:\/\/arctos.gr\/en\/product\/patchcord-optikis-inas-sc-apc-100m\/\">patchcord SC\/APC 100m<\/a> \u03b3\u03b9\u03b1 \u03b5\u03c6\u03b1\u03c1\u03bc\u03bf\u03b3\u03ad\u03c2 \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd. \u0395\u03c0\u03b9\u03c0\u03bb\u03ad\u03bf\u03bd, \u03bc\u03c0\u03bf\u03c1\u03b5\u03af\u03c4\u03b5 \u03bd\u03b1 \u03b4\u03b5\u03af\u03c4\u03b5 \u03c0\u03b5\u03c1\u03b9\u03c3\u03c3\u03cc\u03c4\u03b5\u03c1\u03b1 <a href=\"https:\/\/arctos.gr\/en\/product-category\/buy-products-fiber-optic\/\">fiber optic tools<\/a> \u03ba\u03b1\u03b9 \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc \u03b3\u03b9\u03b1 FTTH \u03b5\u03c1\u03b3\u03b1\u03c3\u03af\u03b5\u03c2.<\/p>\n<h2>\u0393\u03b9\u03b1\u03c4\u03af \u03c4\u03bf \u03bb\u03ac\u03b8\u03bf\u03c2 connector \u03b5\u03c0\u03b7\u03c1\u03b5\u03ac\u03b6\u03b5\u03b9 \u03c4\u03b7 \u03bc\u03ad\u03c4\u03c1\u03b7\u03c3\u03b7;<\/h2>\n<p>\u0388\u03bd\u03b1 \u03bb\u03ac\u03b8\u03bf\u03c2 connector \u03bc\u03c0\u03bf\u03c1\u03b5\u03af \u03bd\u03b1 \u03b4\u03b7\u03bc\u03b9\u03bf\u03c5\u03c1\u03b3\u03ae\u03c3\u03b5\u03b9 \u03c5\u03c8\u03b7\u03bb\u03ae \u03b1\u03c0\u03ce\u03bb\u03b5\u03b9\u03b1 \u03ae \u03ad\u03bd\u03c4\u03bf\u03bd\u03b7 \u03b1\u03bd\u03ac\u03ba\u03bb\u03b1\u03c3\u03b7. \u0388\u03c4\u03c3\u03b9, \u03bc\u03b9\u03b1 \u03bc\u03ad\u03c4\u03c1\u03b7\u03c3\u03b7 \u03bc\u03b5 OTDR \u03ae optical power meter \u03bc\u03c0\u03bf\u03c1\u03b5\u03af \u03bd\u03b1 \u03b4\u03b5\u03af\u03be\u03b5\u03b9 \u03c0\u03c1\u03cc\u03b2\u03bb\u03b7\u03bc\u03b1 \u03c3\u03c4\u03b7 \u03b3\u03c1\u03b1\u03bc\u03bc\u03ae, \u03b5\u03bd\u03ce \u03c3\u03c4\u03b7\u03bd \u03c0\u03c1\u03b1\u03b3\u03bc\u03b1\u03c4\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1 \u03c4\u03bf \u03c0\u03c1\u03cc\u03b2\u03bb\u03b7\u03bc\u03b1 \u03c0\u03c1\u03bf\u03ad\u03c1\u03c7\u03b5\u03c4\u03b1\u03b9 \u03b1\u03c0\u03cc \u03bb\u03ac\u03b8\u03bf\u03c2 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7 \u03ae \u03b2\u03c1\u03ce\u03bc\u03b9\u03ba\u03bf connector.<\/p>\n<p>\u0393\u03b9\u2019 \u03b1\u03c5\u03c4\u03cc, \u03c0\u03c1\u03b9\u03bd \u03ba\u03ac\u03bd\u03b5\u03c4\u03b5 \u03bc\u03ad\u03c4\u03c1\u03b7\u03c3\u03b7, \u03b5\u03bb\u03ad\u03b3\u03be\u03c4\u03b5 \u03c4\u03bf\u03bd \u03c4\u03cd\u03c0\u03bf connector, \u03ba\u03b1\u03b8\u03b1\u03c1\u03af\u03c3\u03c4\u03b5 \u03c3\u03c9\u03c3\u03c4\u03ac \u03c4\u03b7\u03bd \u03ac\u03ba\u03c1\u03b7 \u03c4\u03b7\u03c2 \u03af\u03bd\u03b1\u03c2 \u03ba\u03b1\u03b9 \u03b2\u03b5\u03b2\u03b1\u03b9\u03c9\u03b8\u03b5\u03af\u03c4\u03b5 \u03cc\u03c4\u03b9 \u03b4\u03b5\u03bd \u03ad\u03c7\u03b5\u03c4\u03b5 \u03bc\u03c0\u03b5\u03c1\u03b4\u03ad\u03c8\u03b5\u03b9 APC \u03bc\u03b5 UPC. \u0393\u03b9\u03b1 \u03c0\u03b5\u03c1\u03b9\u03c3\u03c3\u03cc\u03c4\u03b5\u03c1\u03b5\u03c2 \u03c0\u03bb\u03b7\u03c1\u03bf\u03c6\u03bf\u03c1\u03af\u03b5\u03c2, \u03b4\u03b9\u03b1\u03b2\u03ac\u03c3\u03c4\u03b5 \u03ba\u03b1\u03b9 \u03c4\u03bf\u03bd \u03bf\u03b4\u03b7\u03b3\u03cc \u03b3\u03b9\u03b1 \u03c4\u03bf <a href=\"https:\/\/arctos.gr\/en\/ti-einai-to-otdr-optikes-ines\/\">\u03c4\u03b9 \u03b5\u03af\u03bd\u03b1\u03b9 \u03c4\u03bf OTDR<\/a>, \u03ba\u03b1\u03b8\u03ce\u03c2 \u03ba\u03b1\u03b9 \u03c4\u03bf \u03ac\u03c1\u03b8\u03c1\u03bf \u03b3\u03b9\u03b1 \u03c4\u03b1 <a href=\"https:\/\/arctos.gr\/en\/dbm-db-optikes-ines\/\">dBm and dB in Fiber Optics<\/a>.<\/p>\n<h2>\u03a3\u03c5\u03c7\u03bd\u03ac \u03bb\u03ac\u03b8\u03b7 \u03bc\u03b5 SC\/APC \u03ba\u03b1\u03b9 SC\/UPC<\/h2>\n<p>\u03a4\u03bf \u03c0\u03b9\u03bf \u03c3\u03c5\u03c7\u03bd\u03cc \u03bb\u03ac\u03b8\u03bf\u03c2 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u03b1\u03c0\u03b5\u03c5\u03b8\u03b5\u03af\u03b1\u03c2 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7 \u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03bf\u03c5 connector \u03bc\u03b5 \u03bc\u03c0\u03bb\u03b5 connector. \u0391\u03ba\u03cc\u03bc\u03b7 \u03ad\u03bd\u03b1 \u03bb\u03ac\u03b8\u03bf\u03c2 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u03b5\u03c0\u03b9\u03bb\u03bf\u03b3\u03ae patchcord \u03c7\u03c9\u03c1\u03af\u03c2 \u03ad\u03bb\u03b5\u03b3\u03c7\u03bf \u03c4\u03b7\u03c2 \u03b8\u03cd\u03c1\u03b1\u03c2 \u03c4\u03bf\u03c5 \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03bf\u03cd. \u0395\u03c0\u03b9\u03c0\u03bb\u03ad\u03bf\u03bd, \u03b1\u03c1\u03ba\u03b5\u03c4\u03bf\u03af \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03bf\u03af \u03be\u03b5\u03c7\u03bd\u03bf\u03cd\u03bd \u03c4\u03bf\u03bd \u03ba\u03b1\u03b8\u03b1\u03c1\u03b9\u03c3\u03bc\u03cc \u03c0\u03c1\u03b9\u03bd \u03b1\u03c0\u03cc \u03c4\u03b7 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7.<\/p>\n<p>\u0393\u03b9\u03b1 \u03ba\u03b1\u03bb\u03cd\u03c4\u03b5\u03c1\u03bf \u03b1\u03c0\u03bf\u03c4\u03ad\u03bb\u03b5\u03c3\u03bc\u03b1, \u03b1\u03ba\u03bf\u03bb\u03bf\u03c5\u03b8\u03ae\u03c3\u03c4\u03b5 \u03ad\u03bd\u03b1\u03bd \u03b1\u03c0\u03bb\u03cc \u03ba\u03b1\u03bd\u03cc\u03bd\u03b1: \u03b5\u03bb\u03ad\u03b3\u03be\u03c4\u03b5 \u03c4\u03bf \u03c7\u03c1\u03ce\u03bc\u03b1, \u03b4\u03b9\u03b1\u03b2\u03ac\u03c3\u03c4\u03b5 \u03c4\u03b7\u03bd \u03ad\u03bd\u03b4\u03b5\u03b9\u03be\u03b7 \u03c4\u03b7\u03c2 \u03b8\u03cd\u03c1\u03b1\u03c2, \u03ba\u03b1\u03b8\u03b1\u03c1\u03af\u03c3\u03c4\u03b5 \u03c4\u03bf\u03bd connector \u03ba\u03b1\u03b9 \u03bc\u03b5\u03c4\u03ac \u03ba\u03ac\u03bd\u03c4\u03b5 \u03c4\u03b7 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7. \u039c\u03b5 \u03b1\u03c5\u03c4\u03cc\u03bd \u03c4\u03bf\u03bd \u03c4\u03c1\u03cc\u03c0\u03bf \u03bc\u03b5\u03b9\u03ce\u03bd\u03b5\u03c4\u03b5 \u03c4\u03b9\u03c2 \u03b1\u03c0\u03ce\u03bb\u03b5\u03b9\u03b5\u03c2 \u03ba\u03b1\u03b9 \u03b1\u03c0\u03bf\u03c6\u03b5\u03cd\u03b3\u03b5\u03c4\u03b5 \u03ac\u03c3\u03ba\u03bf\u03c0\u03b5\u03c2 \u03b2\u03bb\u03ac\u03b2\u03b5\u03c2.<\/p>\n<h2>SC\/APC vs SC\/UPC: \u03c0\u03bf\u03b9\u03bf \u03bd\u03b1 \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03c9;<\/h2>\n<p>\u0391\u03bd \u03b5\u03c1\u03b3\u03ac\u03b6\u03b5\u03c3\u03c4\u03b5 \u03c3\u03b5 FTTH, GPON \u03ae XGS-PON \u03b5\u03b3\u03ba\u03b1\u03c4\u03ac\u03c3\u03c4\u03b1\u03c3\u03b7, \u03c3\u03c5\u03bd\u03ae\u03b8\u03c9\u03c2 \u03b8\u03b1 \u03c7\u03c1\u03b5\u03b9\u03b1\u03c3\u03c4\u03b5\u03af\u03c4\u03b5 SC\/APC. \u0391\u03bd\u03c4\u03af\u03b8\u03b5\u03c4\u03b1, \u03b1\u03bd \u03bf \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u03c3\u03b1\u03c2 \u03b4\u03b9\u03b1\u03b8\u03ad\u03c4\u03b5\u03b9 UPC \u03b8\u03cd\u03c1\u03b5\u03c2, \u03c4\u03cc\u03c4\u03b5 \u03c0\u03c1\u03ad\u03c0\u03b5\u03b9 \u03bd\u03b1 \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03b5\u03c4\u03b5 SC\/UPC. \u0397 \u03c3\u03c9\u03c3\u03c4\u03ae \u03b5\u03c0\u03b9\u03bb\u03bf\u03b3\u03ae \u03b4\u03b5\u03bd \u03b5\u03be\u03b1\u03c1\u03c4\u03ac\u03c4\u03b1\u03b9 \u03bc\u03cc\u03bd\u03bf \u03b1\u03c0\u03cc \u03c4\u03bf \u03c4\u03b9 \u03ad\u03c7\u03b5\u03c4\u03b5 \u03b4\u03b9\u03b1\u03b8\u03ad\u03c3\u03b9\u03bc\u03bf, \u03b1\u03bb\u03bb\u03ac \u03b1\u03c0\u03cc \u03c4\u03bf \u03c4\u03b9 \u03b1\u03c0\u03b1\u03b9\u03c4\u03b5\u03af \u03b7 \u03b8\u03cd\u03c1\u03b1 \u03ba\u03b1\u03b9 \u03c4\u03bf \u03b4\u03af\u03ba\u03c4\u03c5\u03bf.<\/p>\n<p>\u03a3\u03c5\u03bd\u03bf\u03bb\u03b9\u03ba\u03ac, \u03c3\u03c4\u03bf \u03b5\u03c1\u03ce\u03c4\u03b7\u03bc\u03b1 <strong>SC\/APC vs SC\/UPC<\/strong>, \u03b7 \u03b1\u03c0\u03ac\u03bd\u03c4\u03b7\u03c3\u03b7 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b1\u03c0\u03bb\u03ae: \u03b4\u03b5\u03bd \u03c4\u03b1 \u03bc\u03c0\u03b5\u03c1\u03b4\u03b5\u03cd\u03bf\u03c5\u03bc\u03b5. \u03a7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bc\u03b5 SC\/APC \u03c3\u03b5 APC \u03b8\u03cd\u03c1\u03b5\u03c2 \u03ba\u03b1\u03b9 SC\/UPC \u03c3\u03b5 UPC \u03b8\u03cd\u03c1\u03b5\u03c2. \u0388\u03c4\u03c3\u03b9, \u03c0\u03c1\u03bf\u03c3\u03c4\u03b1\u03c4\u03b5\u03cd\u03bf\u03c5\u03bc\u03b5 \u03c4\u03b1 connectors, \u03bc\u03b5\u03b9\u03ce\u03bd\u03bf\u03c5\u03bc\u03b5 \u03c4\u03b9\u03c2 \u03b1\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2 \u03ba\u03b1\u03b9 \u03ba\u03c1\u03b1\u03c4\u03ac\u03bc\u03b5 \u03c4\u03b7 \u03c3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7 \u03c0\u03b9\u03bf \u03c3\u03c4\u03b1\u03b8\u03b5\u03c1\u03ae.<\/p>\n<p>\u0393\u03b9\u03b1 \u03c0\u03b5\u03c1\u03b9\u03c3\u03c3\u03cc\u03c4\u03b5\u03c1\u03bf\u03c5\u03c2 \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03bf\u03cd\u03c2 \u03bf\u03b4\u03b7\u03b3\u03bf\u03cd\u03c2, \u03bc\u03c0\u03bf\u03c1\u03b5\u03af\u03c4\u03b5 \u03bd\u03b1 \u03b4\u03b5\u03af\u03c4\u03b5 \u03c4\u03bf <a href=\"https:\/\/arctos.gr\/en\/category\/blog-optikon-inon\/\">Fiber Optics Blog<\/a> \u03c4\u03b7\u03c2 ARCTOS. \u0395\u03c0\u03af\u03c3\u03b7\u03c2, \u03b7 <a href=\"https:\/\/www.thefoa.org\/tech\/ref\/testing\/test\/network-troubleshooting.html\" target=\"_blank\" rel=\"noopener\">Fiber Optic Association<\/a> \u03b5\u03be\u03b7\u03b3\u03b5\u03af \u03b3\u03b9\u03b1\u03c4\u03af \u03c4\u03b1 APC connectors \u03b2\u03bf\u03b7\u03b8\u03bf\u03cd\u03bd \u03c3\u03c4\u03b7 \u03bc\u03b5\u03af\u03c9\u03c3\u03b7 \u03c4\u03c9\u03bd \u03c0\u03c1\u03bf\u03b2\u03bb\u03b7\u03bc\u03ac\u03c4\u03c9\u03bd \u03b1\u03c0\u03cc \u03b1\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2 \u03c3\u03b5 singlemode \u03b4\u03af\u03ba\u03c4\u03c5\u03b1.<\/p>\n<h2>\u03a3\u03c5\u03c7\u03bd\u03ad\u03c2 \u0395\u03c1\u03c9\u03c4\u03ae\u03c3\u03b5\u03b9\u03c2 \u03b3\u03b9\u03b1 SC\/APC vs SC\/UPC<\/h2>\n<h3>\u03a0\u03bf\u03b9\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u03b2\u03b1\u03c3\u03b9\u03ba\u03ae \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03b1\u03bd\u03ac\u03bc\u03b5\u03c3\u03b1 \u03c3\u03b5 SC\/APC \u03ba\u03b1\u03b9 SC\/UPC;<\/h3>\n<p>\u0397 \u03b2\u03b1\u03c3\u03b9\u03ba\u03ae \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03b5\u03af\u03bd\u03b1\u03b9 \u03c4\u03bf \u03b3\u03c5\u03ac\u03bb\u03b9\u03c3\u03bc\u03b1 \u03c4\u03b7\u03c2 \u03ac\u03ba\u03c1\u03b7\u03c2 \u03c4\u03b7\u03c2 \u03af\u03bd\u03b1\u03c2. \u03a4\u03bf SC\/APC \u03ad\u03c7\u03b5\u03b9 \u03b3\u03c9\u03bd\u03b9\u03b1\u03ba\u03cc \u03b3\u03c5\u03ac\u03bb\u03b9\u03c3\u03bc\u03b1, \u03b5\u03bd\u03ce \u03c4\u03bf SC\/UPC \u03ad\u03c7\u03b5\u03b9 \u03af\u03c3\u03b9\u03bf ultra physical contact \u03b3\u03c5\u03ac\u03bb\u03b9\u03c3\u03bc\u03b1.<\/p>\n<h3>\u03a4\u03b9 \u03c7\u03c1\u03ce\u03bc\u03b1 \u03ad\u03c7\u03b5\u03b9 \u03c4\u03bf SC\/APC connector;<\/h3>\n<p>\u03a4\u03bf SC\/APC connector \u03b5\u03af\u03bd\u03b1\u03b9 \u03c3\u03c5\u03bd\u03ae\u03b8\u03c9\u03c2 \u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03bf. \u0388\u03c4\u03c3\u03b9, \u03bf \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03cc\u03c2 \u03c4\u03bf \u03be\u03b5\u03c7\u03c9\u03c1\u03af\u03b6\u03b5\u03b9 \u03b5\u03cd\u03ba\u03bf\u03bb\u03b1 \u03b1\u03c0\u03cc \u03c4\u03bf SC\/UPC, \u03c0\u03bf\u03c5 \u03b5\u03af\u03bd\u03b1\u03b9 \u03c3\u03c5\u03bd\u03ae\u03b8\u03c9\u03c2 \u03bc\u03c0\u03bb\u03b5.<\/p>\n<h3>\u039c\u03c0\u03bf\u03c1\u03ce \u03bd\u03b1 \u03b5\u03bd\u03ce\u03c3\u03c9 SC\/APC \u03bc\u03b5 SC\/UPC;<\/h3>\n<p>\u038c\u03c7\u03b9. \u0394\u03b5\u03bd \u03c0\u03c1\u03ad\u03c0\u03b5\u03b9 \u03bd\u03b1 \u03b5\u03bd\u03ce\u03c3\u03b5\u03c4\u03b5 \u03b1\u03c0\u03b5\u03c5\u03b8\u03b5\u03af\u03b1\u03c2 SC\/APC \u03bc\u03b5 SC\/UPC, \u03b3\u03b9\u03b1\u03c4\u03af \u03bf\u03b9 \u03b5\u03c0\u03b9\u03c6\u03ac\u03bd\u03b5\u03b9\u03b5\u03c2 \u03ad\u03c7\u03bf\u03c5\u03bd \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03b5\u03c4\u03b9\u03ba\u03cc \u03b3\u03c5\u03ac\u03bb\u03b9\u03c3\u03bc\u03b1 \u03ba\u03b1\u03b9 \u03bc\u03c0\u03bf\u03c1\u03b5\u03af \u03bd\u03b1 \u03b1\u03c5\u03be\u03b7\u03b8\u03b5\u03af \u03b7 \u03b1\u03c0\u03ce\u03bb\u03b5\u03b9\u03b1 \u03ae \u03bd\u03b1 \u03c0\u03c1\u03bf\u03ba\u03bb\u03b7\u03b8\u03b5\u03af \u03c6\u03b8\u03bf\u03c1\u03ac.<\/p>\n<h3>\u03a0\u03bf\u03b9\u03bf connector \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03b5\u03af\u03c4\u03b1\u03b9 \u03c0\u03b5\u03c1\u03b9\u03c3\u03c3\u03cc\u03c4\u03b5\u03c1\u03bf \u03c3\u03b5 FTTH;<\/h3>\n<p>\u03a3\u03b5 \u03c0\u03bf\u03bb\u03bb\u03ad\u03c2 FTTH \u03ba\u03b1\u03b9 PON \u03b5\u03b3\u03ba\u03b1\u03c4\u03b1\u03c3\u03c4\u03ac\u03c3\u03b5\u03b9\u03c2 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03b5\u03af\u03c4\u03b1\u03b9 SC\/APC, \u03b5\u03c0\u03b5\u03b9\u03b4\u03ae \u03bc\u03b5\u03b9\u03ce\u03bd\u03b5\u03b9 \u03c0\u03b5\u03c1\u03b9\u03c3\u03c3\u03cc\u03c4\u03b5\u03c1\u03bf \u03c4\u03b9\u03c2 \u03b1\u03bd\u03b1\u03ba\u03bb\u03ac\u03c3\u03b5\u03b9\u03c2 \u03ba\u03b1\u03b9 \u03c0\u03c1\u03bf\u03c3\u03c6\u03ad\u03c1\u03b5\u03b9 \u03c0\u03b9\u03bf \u03c3\u03c4\u03b1\u03b8\u03b5\u03c1\u03ae \u03bb\u03b5\u03b9\u03c4\u03bf\u03c5\u03c1\u03b3\u03af\u03b1.<\/p>\n<h3>\u03a0\u03cc\u03c4\u03b5 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bc\u03b5 SC\/UPC;<\/h3>\n<p>\u03a7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03bf\u03cd\u03bc\u03b5 SC\/UPC \u03cc\u03c4\u03b1\u03bd \u03bf \u03b5\u03be\u03bf\u03c0\u03bb\u03b9\u03c3\u03bc\u03cc\u03c2 \u03b4\u03b9\u03b1\u03b8\u03ad\u03c4\u03b5\u03b9 UPC \u03b8\u03cd\u03c1\u03b5\u03c2. \u0393\u03b9\u03b1 \u03c0\u03b1\u03c1\u03ac\u03b4\u03b5\u03b9\u03b3\u03bc\u03b1, \u03bc\u03c0\u03bf\u03c1\u03b5\u03af \u03bd\u03b1 \u03c7\u03c1\u03b7\u03c3\u03b9\u03bc\u03bf\u03c0\u03bf\u03b9\u03b7\u03b8\u03b5\u03af \u03c3\u03b5 data networks, patch panels, \u03c3\u03c5\u03c3\u03ba\u03b5\u03c5\u03ad\u03c2 \u03bc\u03ad\u03c4\u03c1\u03b7\u03c3\u03b7\u03c2 \u03ba\u03b1\u03b9 \u03b5\u03c1\u03b3\u03b1\u03c3\u03c4\u03b7\u03c1\u03b9\u03b1\u03ba\u03ad\u03c2 \u03c3\u03c5\u03bd\u03b4\u03ad\u03c3\u03b5\u03b9\u03c2.<\/p>","protected":false},"excerpt":{"rendered":null,"protected":false},"author":1,"featured_media":4175,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5,193],"tags":[211,214,212,213,210,208,209,216,112,215],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SC\/APC vs SC\/UPC | \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2<\/title>\n<meta name=\"description\" content=\"SC\/APC vs SC\/UPC: \u03bc\u03ac\u03b8\u03b5 \u03c4\u03b9\u03c2 \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b1 connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd, \u03c4\u03b7\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03bf\u03c6\u03ae \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2, \u03c4\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03c3\u03b5 FTTH \u03ba\u03b1\u03b9 \u03c4\u03b9 \u03bd\u03b1 \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03b5\u03b9\u03c2.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/arctos.gr\/en\/sc-apc-vs-sc-upc\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SC\/APC vs SC\/UPC | \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2\" \/>\n<meta property=\"og:description\" content=\"SC\/APC vs SC\/UPC: \u03bc\u03ac\u03b8\u03b5 \u03c4\u03b9\u03c2 \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b1 connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd, \u03c4\u03b7\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03bf\u03c6\u03ae \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2, \u03c4\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03c3\u03b5 FTTH \u03ba\u03b1\u03b9 \u03c4\u03b9 \u03bd\u03b1 \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03b5\u03b9\u03c2.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/arctos.gr\/en\/sc-apc-vs-sc-upc\/\" \/>\n<meta property=\"og:site_name\" content=\"ARCTOS\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-06T17:18:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-06T17:24:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1672\" \/>\n\t<meta property=\"og:image:height\" content=\"941\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/arctos.gr\/#\/schema\/person\/03d99f6ff15b2247f52b3fcfc56c4359\"},\"headline\":\"SC\/APC vs SC\/UPC: \u03a0\u03bf\u03b9\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2;\",\"datePublished\":\"2026-08-06T17:18:28+00:00\",\"dateModified\":\"2026-08-06T17:24:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/\"},\"wordCount\":329,\"publisher\":{\"@id\":\"https:\/\/arctos.gr\/#organization\"},\"image\":{\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png\",\"keywords\":[\"connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd\",\"FTTH connector\",\"patchcord SC\/APC\",\"patchcord SC\/UPC\",\"SC APC vs SC UPC\",\"SC\/APC\",\"SC\/UPC\",\"\u03bc\u03c0\u03bb\u03b5 connector \u03bf\u03c0\u03c4\u03b9\u03ba\u03ae\u03c2 \u03af\u03bd\u03b1\u03c2\",\"\u03bf\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u03af\u03bd\u03b5\u03c2\",\"\u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03bf connector \u03bf\u03c0\u03c4\u03b9\u03ba\u03ae\u03c2 \u03af\u03bd\u03b1\u03c2\"],\"articleSection\":[\"Blog\",\"\u039f\u03b4\u03b7\u03b3\u03bf\u03af \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/\",\"url\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/\",\"name\":\"SC\/APC vs SC\/UPC | \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2\",\"isPartOf\":{\"@id\":\"https:\/\/arctos.gr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png\",\"datePublished\":\"2026-08-06T17:18:28+00:00\",\"dateModified\":\"2026-08-06T17:24:32+00:00\",\"description\":\"SC\/APC vs SC\/UPC: \u03bc\u03ac\u03b8\u03b5 \u03c4\u03b9\u03c2 \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b1 connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd, \u03c4\u03b7\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03bf\u03c6\u03ae \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2, \u03c4\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03c3\u03b5 FTTH \u03ba\u03b1\u03b9 \u03c4\u03b9 \u03bd\u03b1 \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03b5\u03b9\u03c2.\",\"breadcrumb\":{\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#primaryimage\",\"url\":\"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png\",\"contentUrl\":\"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png\",\"width\":1672,\"height\":941,\"caption\":\"\u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03b1\u03bd\u03ac\u03bc\u03b5\u03c3\u03b1 \u03c3\u03b5 SC\/APC \u03ba\u03b1\u03b9 SC\/UPC connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd \u03b3\u03b9\u03b1 FTTH, PON \u03ba\u03b1\u03b9 \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03ad\u03c2 \u03b5\u03b3\u03ba\u03b1\u03c4\u03b1\u03c3\u03c4\u03ac\u03c3\u03b5\u03b9\u03c2.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u0391\u03c1\u03c7\u03b9\u03ba\u03ae\",\"item\":\"https:\/\/arctos.gr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\/\/arctos.gr\/category\/blog-optikon-inon\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"SC\/APC vs SC\/UPC: \u03a0\u03bf\u03b9\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2;\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/arctos.gr\/#website\",\"url\":\"https:\/\/arctos.gr\/\",\"name\":\"ARCTOS\",\"description\":\"\u0395\u03bc\u03c0\u03cc\u03c1\u03b9\u03bf \u03bf\u03c1\u03b3\u03ac\u03bd\u03c9\u03bd \u03a3\u03c5\u03b3\u03ba\u03cc\u03bb\u03bb\u03b7\u03c3\u03b7\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd ( splicer ) , \u038c\u03c1\u03b3\u03b1\u03bd\u03b1 \u0395\u03bb\u03ad\u03b3\u03c7\u03bf\u03c5 \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd , \u039a\u03b1\u03b8\u03b1\u03c1\u03b9\u03c3\u03c4\u03b9\u03ba\u03ac \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd , \u0388\u03c1\u03b3\u03b1\u03bb\u03b5\u03af\u03b1 \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd , Cleaver , OTDR . \u0395\u03c0\u03b9\u03c3\u03ba\u03b5\u03c5\u03ae Splicer. \u0395\u03bd\u03bf\u03b9\u03ba\u03af\u03b1\u03c3\u03b7 Splicer\",\"publisher\":{\"@id\":\"https:\/\/arctos.gr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/arctos.gr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/arctos.gr\/#organization\",\"name\":\"Arctos\",\"url\":\"https:\/\/arctos.gr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/arctos.gr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/arctos.gr\/wp-content\/uploads\/2022\/12\/logo-arctos.png\",\"contentUrl\":\"https:\/\/arctos.gr\/wp-content\/uploads\/2022\/12\/logo-arctos.png\",\"width\":550,\"height\":180,\"caption\":\"Arctos\"},\"image\":{\"@id\":\"https:\/\/arctos.gr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/arctos.gr\/#\/schema\/person\/03d99f6ff15b2247f52b3fcfc56c4359\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/arctos.gr\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/2a7ac55652470f3bfb7c0446996301bc?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/2a7ac55652470f3bfb7c0446996301bc?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\/\/arctos.gr\"],\"url\":\"https:\/\/arctos.gr\/en\/author\/arctadmn\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SC\/APC vs SC\/UPC | \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2","description":"SC\/APC vs SC\/UPC: \u03bc\u03ac\u03b8\u03b5 \u03c4\u03b9\u03c2 \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b1 connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd, \u03c4\u03b7\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03bf\u03c6\u03ae \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2, \u03c4\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03c3\u03b5 FTTH \u03ba\u03b1\u03b9 \u03c4\u03b9 \u03bd\u03b1 \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03b5\u03b9\u03c2.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/arctos.gr\/en\/sc-apc-vs-sc-upc\/","og_locale":"en_US","og_type":"article","og_title":"SC\/APC vs SC\/UPC | \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2","og_description":"SC\/APC vs SC\/UPC: \u03bc\u03ac\u03b8\u03b5 \u03c4\u03b9\u03c2 \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b1 connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd, \u03c4\u03b7\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03bf\u03c6\u03ae \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2, \u03c4\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03c3\u03b5 FTTH \u03ba\u03b1\u03b9 \u03c4\u03b9 \u03bd\u03b1 \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03b5\u03b9\u03c2.","og_url":"https:\/\/arctos.gr\/en\/sc-apc-vs-sc-upc\/","og_site_name":"ARCTOS","article_published_time":"2026-08-06T17:18:28+00:00","article_modified_time":"2026-08-06T17:24:32+00:00","og_image":[{"width":1672,"height":941,"url":"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#article","isPartOf":{"@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/"},"author":{"name":"admin","@id":"https:\/\/arctos.gr\/#\/schema\/person\/03d99f6ff15b2247f52b3fcfc56c4359"},"headline":"SC\/APC vs SC\/UPC: \u03a0\u03bf\u03b9\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2;","datePublished":"2026-08-06T17:18:28+00:00","dateModified":"2026-08-06T17:24:32+00:00","mainEntityOfPage":{"@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/"},"wordCount":329,"publisher":{"@id":"https:\/\/arctos.gr\/#organization"},"image":{"@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#primaryimage"},"thumbnailUrl":"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png","keywords":["connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd","FTTH connector","patchcord SC\/APC","patchcord SC\/UPC","SC APC vs SC UPC","SC\/APC","SC\/UPC","\u03bc\u03c0\u03bb\u03b5 connector \u03bf\u03c0\u03c4\u03b9\u03ba\u03ae\u03c2 \u03af\u03bd\u03b1\u03c2","\u03bf\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u03af\u03bd\u03b5\u03c2","\u03c0\u03c1\u03ac\u03c3\u03b9\u03bd\u03bf connector \u03bf\u03c0\u03c4\u03b9\u03ba\u03ae\u03c2 \u03af\u03bd\u03b1\u03c2"],"articleSection":["Blog","\u039f\u03b4\u03b7\u03b3\u03bf\u03af \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/","url":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/","name":"SC\/APC vs SC\/UPC | \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2","isPartOf":{"@id":"https:\/\/arctos.gr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#primaryimage"},"image":{"@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#primaryimage"},"thumbnailUrl":"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png","datePublished":"2026-08-06T17:18:28+00:00","dateModified":"2026-08-06T17:24:32+00:00","description":"SC\/APC vs SC\/UPC: \u03bc\u03ac\u03b8\u03b5 \u03c4\u03b9\u03c2 \u03b4\u03b9\u03b1\u03c6\u03bf\u03c1\u03ad\u03c2 \u03c3\u03c4\u03b1 connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd, \u03c4\u03b7\u03bd \u03b5\u03c0\u03b9\u03c3\u03c4\u03c1\u03bf\u03c6\u03ae \u03c3\u03ae\u03bc\u03b1\u03c4\u03bf\u03c2, \u03c4\u03b7 \u03c7\u03c1\u03ae\u03c3\u03b7 \u03c3\u03b5 FTTH \u03ba\u03b1\u03b9 \u03c4\u03b9 \u03bd\u03b1 \u03b5\u03c0\u03b9\u03bb\u03ad\u03be\u03b5\u03b9\u03c2.","breadcrumb":{"@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#primaryimage","url":"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png","contentUrl":"https:\/\/arctos.gr\/wp-content\/uploads\/2026\/08\/sc-apc-vs-sc-upc-optikes-ines-arctos.png","width":1672,"height":941,"caption":"\u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03b1\u03bd\u03ac\u03bc\u03b5\u03c3\u03b1 \u03c3\u03b5 SC\/APC \u03ba\u03b1\u03b9 SC\/UPC connectors \u03bf\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u03b9\u03bd\u03ce\u03bd \u03b3\u03b9\u03b1 FTTH, PON \u03ba\u03b1\u03b9 \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03ad\u03c2 \u03b5\u03b3\u03ba\u03b1\u03c4\u03b1\u03c3\u03c4\u03ac\u03c3\u03b5\u03b9\u03c2."},{"@type":"BreadcrumbList","@id":"https:\/\/arctos.gr\/sc-apc-vs-sc-upc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0391\u03c1\u03c7\u03b9\u03ba\u03ae","item":"https:\/\/arctos.gr\/"},{"@type":"ListItem","position":2,"name":"Blog","item":"https:\/\/arctos.gr\/category\/blog-optikon-inon\/"},{"@type":"ListItem","position":3,"name":"SC\/APC vs SC\/UPC: \u03a0\u03bf\u03b9\u03b1 \u03b5\u03af\u03bd\u03b1\u03b9 \u03b7 \u0394\u03b9\u03b1\u03c6\u03bf\u03c1\u03ac \u03c3\u03c4\u03b9\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ad\u03c2 \u038a\u03bd\u03b5\u03c2;"}]},{"@type":"WebSite","@id":"https:\/\/arctos.gr\/#website","url":"https:\/\/arctos.gr\/","name":"ARCTOS","description":"\u0395\u03bc\u03c0\u03cc\u03c1\u03b9\u03bf \u03bf\u03c1\u03b3\u03ac\u03bd\u03c9\u03bd \u03a3\u03c5\u03b3\u03ba\u03cc\u03bb\u03bb\u03b7\u03c3\u03b7\u03c2 \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd ( splicer ) , \u038c\u03c1\u03b3\u03b1\u03bd\u03b1 \u0395\u03bb\u03ad\u03b3\u03c7\u03bf\u03c5 \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd , \u039a\u03b1\u03b8\u03b1\u03c1\u03b9\u03c3\u03c4\u03b9\u03ba\u03ac \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd , \u0388\u03c1\u03b3\u03b1\u03bb\u03b5\u03af\u03b1 \u039f\u03c0\u03c4\u03b9\u03ba\u03ce\u03bd \u0399\u03bd\u03ce\u03bd , Cleaver , OTDR . \u0395\u03c0\u03b9\u03c3\u03ba\u03b5\u03c5\u03ae Splicer. \u0395\u03bd\u03bf\u03b9\u03ba\u03af\u03b1\u03c3\u03b7 Splicer","publisher":{"@id":"https:\/\/arctos.gr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/arctos.gr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/arctos.gr\/#organization","name":"Arctos","url":"https:\/\/arctos.gr\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/arctos.gr\/#\/schema\/logo\/image\/","url":"https:\/\/arctos.gr\/wp-content\/uploads\/2022\/12\/logo-arctos.png","contentUrl":"https:\/\/arctos.gr\/wp-content\/uploads\/2022\/12\/logo-arctos.png","width":550,"height":180,"caption":"Arctos"},"image":{"@id":"https:\/\/arctos.gr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/arctos.gr\/#\/schema\/person\/03d99f6ff15b2247f52b3fcfc56c4359","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/arctos.gr\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/2a7ac55652470f3bfb7c0446996301bc?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2a7ac55652470f3bfb7c0446996301bc?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/arctos.gr"],"url":"https:\/\/arctos.gr\/en\/author\/arctadmn\/"}]}},"_links":{"self":[{"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/posts\/4174"}],"collection":[{"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/comments?post=4174"}],"version-history":[{"count":0,"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/posts\/4174\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/media\/4175"}],"wp:attachment":[{"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/media?parent=4174"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/categories?post=4174"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/arctos.gr\/en\/wp-json\/wp\/v2\/tags?post=4174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}